Description
Product Details
The EECPC 3790A fully meets all proposed PMP requirements for Euro 5 and Euro 6 (VI) regulations for light and heavy-duty vehicles. It builds upon the proven rugged, reliable, and highly repeatable performance of TSI’s butanol CPC technology. The full-flow design incorporates new improvement and performance features, such as anti-spill/anti-flooding design, condensate removal system, and removable saturator for easy maintenance. EECPC 3790A has a lower particle size detection limit (D 50 ) of 23 nm to meet the PMP’s requirement for eliminating measurement of volatile and semi-volatile nanoparticles formed by nucleation of gaseous compounds.
The TSI Models 379020A Rotating Disk Thermodiluter and 379030 Thermal Conditioner can be used with the EECPC to eliminate nanoparticles formed by condensation of volatile compounds found in engine exhaust, as required in GRPE/PMP regulations.
Features
- Meets the PMP lower particle size detection limit at the defined D 10 , D 25 , D 50 and D 90 counting efficiencies
- Achieves a linear response to particle concentration from 1 to 10,000 particles/ cm3 with R2 >0.95
- Achieves a counting accuracy of ± 10% against a traceable standard
- Operates under full flow conditions using single particle counting
- Calibration is in full compliance with PMP
- Achieves readability of 0.1 particles/cm3
- Internal pulse-height monitor to indicate measurement quality
- 10 Hz data rate for modal analysis
Applications
- Diesel and gasoline engine emissions testing
Catalogues
Application Notes
- TSI PER-001 Printer Emission Measurements at TSI Application Note
- TSI CPC-001 Live Time Counting AppNote
- TSI CPC-002 Choosing the Right CPC for Your Application Application Note
- TSI CPC-003 Fundamentals of Condensation Particle Counters and Scanning Mobility Particle Sizer Spectrometers Application Note
- TSI EM-003 Calibration Process of the Volatile Particle Remover for Engine Exhaust Measurements Application Note
- TSI EECPC-001 Flow Rate Correction for the Model 3790 Engine Exhaust Condensation Particle Counter AppNote
- TSI EECPC-002 EECPC Calibration Order the Right Equipment AppNote
- TSI EM-004 Generating Emery Oil Aerosol for Calibration Application Note
- TSI EECPC-003 Explaining the k – factor Concentration Correction Multiplier AppNote
- TSI EECPC-005 EECPC Calibration Order the Right Equipment AppNote
Accessories
TSI 3032 Vacuum Pump